Google+

Menu

user_mobilelogo

DAIN

Double inlet direct driven centrifugal fans with forward curved blades

  • Fans manufactured with galvanized steel, special painting or stainless steel execution possible
  • Housing with galvanized steel, assembled with cold welding TOX production tools
  • Forward curved impellers, tablock execution or unique long blade type, selected in accordance to the best compromise between duty and max efficiency, as requested by European directives
  • Electric motors, closed IP44/55 or open IP20  with thermal protector ( TOP ) always included
  • Max airflow 15000 m3/h  
  • Max static pressure 1500 Pa

 

Fan typeFan codeDrawingLab curveErP
2015
Motor power [Wout]PoleSpeedMotor IPPower supply
DAIN 6/7 XPL SM00094 1F 4P 1V + FLSV00070

Drw

Test

ok1054144230/1/50
DAIN 6/9 XPL 201100R 3F 2P 1V + FL110103T

Drw

Test

ok7502120230-400/3/50-60
DAIN 7/7 XPL MTR.4P.147.1V.IP55 1F 4P 1V110100P

Drw

Test

ok1474155230/1/50
DAIN 7/7 XPL MTR.4P.147.3V 1F 4P 3V + FL1110102Q

Drw

Test

ok1474344230/1/50
DAIN 7/7 MTR.4P.147.1V.IP55 1F 4P 1V 60Hz110101D

Drw

Test

1474155230/1/60
DAIN 9/7 XPL 2011017 1F 4P 1V 1101030DrwTestok 4204155230/1/50
DAIN 9/7 XPL2 201101A 1F 4P 3V + FL1101035

Drw

Test

ok4004320230/1/50
DAIN 9/7 XPL 201100M 1F 4P 3V1101015

Drw

Test

ok4204320230/1/50
DAIN 9/7 XPL 2011001 1F 4P 3V + FL1101018

Drw

Test

ok4204344230/1/50
DAIN 9/7 XPL3 201100S 3F 4P 1V + VERN110101H

Drw

Test

ok4204155230-400/3/50-60
DAIN 9/9 SM00107 1F 6P 3VSV00108

Drw

Test

1476320230/1/50-60
DAIN 9/9 XPL 2011017 1F 4P 1V110102T

Drw

Test

ok4204155230/1/50-60
DAIN 9/9 XPL 2011001 1F 4P 3V1101017

Drw

Test

ok4204344230/1/50
DAIN 9/9 XPL 201100B 1F 4P 1V + FL110100D

Drw

Test

ok5504144230/1/50
DAIN 9/9 XPL 201100S 3F 4P 1VSV00163DrwTestok4204155230-400/3/50-60
DAIN 9/9 R2 XPL 2011007 1F 4P 1VSV00042

Drw

Test

ok4204144230/1/50
DAIN 10/8 SM00108 1F 6P 3VSV00109

Drw

Test

2456320230/1/50-60
DAIN 10/8 XPL 2011002 1F 6P 3V1101000

Drw

Test

ok2456320230/1/50
DAIN 10/8 XPL2 201101B 1F 4P 3V + FL1101036

Drw

Test

ok5504320230/1/50
DAIN 10/8 XPL MTR.4P.550.1V 1F 4P 1V110100M

Drw

Test

ok550 4144 230/1/50
DAIN 10/8 XPL 2011018 1F 4P 1V + FL1110101G

Drw

Test

ok550 4144 230/1/50
DAIN 10/8 XPL SM00109 3F 4P 2V 110102C

Drw

Test

ok9004255400-400/3/50
DAIN 10/10 SM00108 1F 6P 3VSV00110

Drw

Test

2456320230/1/50-60
DAIN 10/10 XPL 201100C 1F 6P 3V110100V

Drw

Test

ok3706320 230/1/50
DAIN 10/10 XPL 201101P 1F 4P 3V + FL110103V

Drw

Test

ok7504320 230/1/50
DAIN 10/10 XPL 2011018 1F 4P 1V110102V

Drw

Test

ok550 4144 230/1/50
DAIN 10/10 XPL MTR.4P.550.3V.T 1F 4P 3V1101003

Drw

Test

ok550 4344 230/1/50
DAIN 10/10 XPL2 2011016 3F 4P 2V110103D

Drw

Test

ok9004255400/3/50
DAIN 12/9 XPL2 201100D 1F 6P 1V110100N

Drw

Test

ok5606120230/1/50
DAIN 12/9 XPL 2011009 1F 6P 1V1101013

Drw

Test

ok5606154230/1/50
DAIN 12/9 XPL 201100A 1F 6P 1V1101014

Drw

Test

ok7466144230/1/50
DAIN 12/9 XPL 201100P 3F 6P 1V110101RDrwTestok11006155230-400/3/50
DAIN 12/9 XPL2 2011012 3F 4P 2V110102A

Drw

Test

ok15004220400-400/3/50
DAIN 12/9 XPL3 201100V 3F 4P 1V1101023

Drw

Test

ok15004120230-400/3/50
DAIN 12/12 XPL 2011009 1F 6P 1V110100S

Drw

Test

ok5606154230/1/50
DAIN 12/12 XPL 201100A 1F 6P 1V + SB1101010

Drw

Test

ok7466144230/1/50
DAIN 12/12 XPL 201100U 1F 6P 3V + FL1101022

Drw

Test

ok7356355230/1/50
DAIN 12/12 XPL 201100N 1F 6P 1V110101A

Drw

Test

ok11006110230/1/50
DAIN 12/12 XPL 201100P 3F 6P 1V110101C

Drw

Test

ok11006155 230-400/3/50
DAIN 12/12 XPL3 2011015 3F 6P 2V110103L

Drw

Test

ok11006255400-400/3/50
DAIN 12/12 XPL 201100V 3F 4P 1V1101028

Drw

Test

ok15004120230-400/3/50
DAIN 12/12 201100E 3F 6P 1V + Tel110102N

Drw

Test

22006155230-400/3/50-60
DAIN 12/12 XPL2 2011019 3F 4P 2V + FLSV00138

Drw

Test

ok30004255400-400/3/50-60
DAIN 15/11 XPL4 201101E 3F 6P 1V + TEL + FL110103G

Drw

Test

ok22006155400/3/50
DAIN 15/15 XPL 201100E 3F 6P 1V110100Z

Drw

Test

ok 220061 55 230-400/3/50

The data contained in the table can be modified without notice

DAIN

DA-IN

SAPPE

SAPPE_PLT60-

CBT

DARE

dare

DTA

DTA

MCK

mck

DAREB

dareb

RFB

dare

VDI

VDI

SAREB

sareb

AX

AX

MCT 400

bbf

ErP "Energy related Products"

ERP


All (1) the fans circulating within the European community of power between 125 W and 500 kW from January 2013 will be in accordance with Regulation (EU) N.327/2011 Commission. The efficiency of the fans to meet the European standards, must reach a minimum level.

read more »

Laboratory tests

Test di laboratorio


Design and supply of laboratories for testing fans and control of air flow. Laboratories comply with AMCA 210/ISO 5801.

read more »